Live, kg/min 2dp (3dp is available
with native I32)
Live from onboard T/P Board
sensor
Hose Quantity per
electronic tote
Last end of delivery, 3dp
Last end of delivery, 3dp
Last end of delivery, 1dp
Start of last delivery, 0dp
End of last delivery, 0dp
0 = free; 1 = locked. Acts as a
nozzle up reason to prevent fill or
stop fill. These things to right are
no longer in use ->Setting the
C4000 B code to 1xxx will continue
to apply the lock status after
dispenser re-power, else the
dispenser will re-power in stand-
alone mode
0.00->655.35, 2dp implied. Size
limited by U16 register. Stored as
U32, 3dp.
0-350.0, bar 1dp. Internally sets
overpressure cutoff (Max pressure
setting is now redundant
Sequence rate Low to
Med bank
0,1,2 (fast, med, slow). internally
does not exist, sets global bank
switch over rate! Only Side 1
changes. Side 2 is ignored to stop
toggling of shared global setting.
Backwards compatible with
existing tool if 10,20,30 (10,2.0,3.0)
etc is sent, sets the closest setting
(1.0kg slow, 3.0kg med, 5.0kg fast)
Sequence rate Med to
High bank
Register is not linked to config. Use
204 to change sequencing speed.
Density factor, 4dp (10000 ->
1.0000)
0 (0b00) no switch pressed. 1
(0b01) start. 2 (0b10) stop. 3
(0b11) Start & stop.