The end of sale indicator allows you to determine the reason why the last fill ended.
This can be very useful for fault finding and diagnostics.
To View the End of Sale indicators:
▪ Press and release the Parameter switch until the required hose number is
displayed.
▪ The number in the unit price display is the end of sale indicator for the hose
number shown
See the table below for the meaning of the number displayed.
Nozzle switch de-activated (does not
apply to push to start dispensers).
Preset or temperature compensated value
reached. Normal end of sale message
for temperature compensated and Fast
Fill dispensers.
Fill timed out. Start button pressed, or
nozzle lifted, without flow.
Check inlet gas pressure.
Check solenoid operation.
Refer Solenoid Problems
Check nozzle and breakaway
for blockages.
The dispenser was stopped by a remote
device such as a Point of Sale (POS) or
Compac Communicator.
Check that the point of sale is
not sending a stop command
and is correctly configured.
Maximum display value reached.
Check display resolution (Sr)
setting. Refer Display
Resolution
An error has occurred. The error will be
shown on the main display.
Check error code reason.
Refer Error Codes
Outputs sequenced normally and
dispenser finished on the low flow cutoff
setting. Normal end of sale message for
regulator controlled dispensers
Parity error on main display. This is
caused by a fault in the display or a bad
connection in the display wiring loom.
Check displays are dry and all
connections tight. Try
swapping with another display
if available.