44.
Servicing
Filter Element Replacement
The coalescing filters are designed to trap dirt, moisture, oil, and other debris that
may damage the valve seals.
Before you start, make sure you have:
- A seal kit - Part number FC-FIL-0001
1 x filter
1 x filter bowl O-ring seal
- O-ring lubricant
To remove the coalescing filter:
- Degas the dispenser.
- Drain the coalescing filters if they have not been drained already.
- Unscrew the filter bowl(s) with a spanner on the 22mm hex nut at the base of
the filter bowl.
- Remove the filter element.
- Clean all oil and dirt off the components with a clean cloth.
To install the new coalescing filter:
- Insert the new filter element and lubricated filter bowl O-ring seal.
CAUTION: O-rings that are subjected to natural gas at high pressure swell when
exposed to air. Once swollen, they cannot be reused and must be replaced.
Filter Bowl O-ring Seal
Filter Element
Filter Bowl
Drain Plug