14.
Dispenser Set
-Up
Minimum Flow Rate
The minimum flow rate (LFA and LFb) is the low flow cut-off at the end of the fill.
LFA is the minimum flow rate of side A of the dispenser.
LFb is the minimum flow rate of side B of the dispenser.
These values are adjustable and can be set between 0.5 99 𝑘𝑔 𝑚𝑖𝑛
.
CAUTION: Do not set the minimum flow rate so that it is equal to or above the maximum
flow rate.
To Adjust the Minimum Flow Rate
- Make sure that the dispenser is idle, with the nozzle in its holster.
- Press and release the Parameter switch until the required minimum flow rate
is displayed. (LFA or LFb)
- Enter the new minimum flow rate.
NOTE: Each press of the Parameter switch passes you over a digit in a setting, making
the digit blink. Holding the switch down for more than a second changes whichever digit
is currently displayed. If you want to pass over a setting without changing any digits,
keep pressing and releasing the switch.
NOTE: The Compac factory default setting is 1.0 𝑘𝑔 𝑚𝑖𝑛
.
- Let the menu time out so that the value and quantity amounts are displayed.
Maximum Flow Rate
The maximum flow rate (HFA and HFb) is the high flow cut-off for when the flow
through the dispenser is too high.
HFA is the maximum flow rate of side A of the dispenser.
HFb is the maximum flow rate of side B of the dispenser
These values are adjustable and can be set between 1 9999 𝑘𝑔 𝑚𝑖𝑛
.
lFA 00.0

Table of Contents

Other manuals for Compac C5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compac C5000 and is the answer not in the manual?

Compac C5000 Specifications

General IconGeneral
BrandCompac
ModelC5000
CategoryControl Unit
LanguageEnglish

Related product manuals