41.
Servicing
Checking the Dispenser for Leaks
Before you start, make sure you have:
- Soapy water
To check the dispenser for leaks:
CAUTION: Be careful not to spray or drip water into any of the dispenser electronics
when checking for leaks.
- Apply soapy water to all joins in the assemblies and fittings on the inside and
outside of the dispenser, including the hose.
If bubbles form, there is a leak with that assembly or fitting. The fitting may require
tightening, or the seals might need to be replaced.
DANGER: You must isolate the gas supply and depressurise the dispenser before
disassembling any component or adjusting any fitting. Serious injury may result if
components are removed while the dispenser is under pressure.
- Threaded SAE Fittings.
- Adjustable Threaded SAE Fittings.
- Compression Fittings.
- To remedy a leak, refer to the appropriate section, depending on the leak is
location.
- After checking for leaks, wipe any excess water off the dispenser to prevent
corrosion.