43.
Servicing
Checking the Three-Way Refuelling Valve Operation
Before you start, make sure you have:
- Soapy water
Check the Sealing of the Three-Way Refuelling Valve
To check the sealing of the three-way refuelling valve, apply soapy water to the
valve.
If bubbles form, there is a leak, in which case you should replace the three-way
refuelling valve seals.
To check the operation of the three-way refuelling valve:
To check the operation of the three-way refuelling valve, do a test fill to check that
the valve is filling the vehicle, and venting properly when you disconnect it from the
vehicle.
If bubbles form, there is a leak, in which case you should replace the three-way
refuelling valve seals.
Draining the Coalescing Filter
Before you start, make sure you have:
- A 3/16" hex key
To drain the coalescing filter:
- De-gas the dispenser.
- Open the dispenser access doors.
- Unscrew the drain plug from the bottom of the filter cover.
- Allow all oil and water to drain from the filter*.
- If excessive amounts of oil and water are present, remove and replace the
coalescing filters.
- Screw in the drain plug and repeat steps 1 to 4 for all additional filters.
*NOTE: Make sure you dispose of any fluids responsibly.

Table of Contents

Other manuals for Compac C5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compac C5000 and is the answer not in the manual?

Compac C5000 Specifications

General IconGeneral
BrandCompac
ModelC5000
CategoryControl Unit
LanguageEnglish

Related product manuals