To install the new C5000 software
- Switch off the power supply to the dispenser.
DANGER: Never remove any electrical components without first switching
off the power to the dispenser. Failure to turn off the power could result in
an electric shock.
- Remove the flameproof box lid to gain access to the C5000 Processor
board.
- Install the USB stick for the software that you want to install. If there is
a coms or GPIO card installed on the C5000 processor board, you might
have to remove it.
- Reinstalled the lid on the flameproof box
DANGER: Before replacing the lid on the flameproof box, make sure that
the O-ring is not damaged, and is seated properly in its groove. If the O-ring
is damaged and needs replacing, replace it with an O-ring of the same size
and specification (176 N70).
- Switch on the power supply to the dispenser.
- The Display will display hold. The display will change from hold to calib,
this mean that the software has been upgraded.
- Press the K-Factor board button on the K-Factor board to clear the caib
from the display and sync the K-Factor board settings will the C5000
processor board.
- Check the dispenser operation Checking Dispenser Operation.