CSAT-5060 C-Band Transceivers Revision 1
Appendix A MN/CSAT5060.IOM
A–17
CSAT Remote Commands
Parameter
Type Command Arguments Description of arguments
Response to
Command Query
Response to
Query
Retrieve
Redundancy
Status
N/A
37 bytes,
alpha numerical
Query only.
Used to Query the utility status of the CSAT
Example: RRS=’cr’
R 5V=5.0’cr’
R 12V=11.8’cr’
TX SW=OK’cr’
RX SW=OK’cr’’lf’
Note: Access via Online unit.
N/A RRS? RRS=x….x
See Note 2
Retrieve
Maintenance
Status
N/A
175 bytes,
alpha numerical
Query only.
Used to Query the maintenance status of the CSAT
Example: RMS=’cr’
24VT=023.9’cr’
20VT=020.3’cr’
12VT=012.0’cr’
10VT=010.2’cr’
P5VT=005.0’cr’
N5VT=-05.0’cr’
USYN=008.2’cr’
UIFL=003.9’cr’
DSYN=006.3’cr’
DIFL=003.8’cr’
REFV=002.9’cr’
LNAC=081.9’cr’
FANC=541.0’cr’
UTMP= 37.0’cr’
POWR=25.0-’cr’
DTMP= 34.0’cr’’lf’
N/A RMS? RMS=x….x
See Note 2