Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–14 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Status
Returns the alarm status of the unit, response is semicolon-delimited.
EXAMPLE: <1/CAS?{CR}
>0001/CAS=a;b;c;d;e;f;g;h;i;j;k;I;m;n;o;p;q;r;s;t;u;v;w;x;y;{CR}{LF} where:
a thru z where 0=FT, 1=OK, 2=AL, 3=NO, 4=YS, 5=MS, 6=??, or 7=NA (SEE
NOTES 2 AND 3)
a=+24V Power Supply
b=+24V Switch Power Supply
c=+13/18V LNB Power Supply (SEE NOTE 4)
d=+13.5V Power Supply
e=+10V Power Supply
f=+10V1 Amplifier Power Supply
g=+10V2 Amplifier Power Supply (SEE NOTE 4)
h=+7.8V Power Supply
i=+5.8V Power Supply
j=+2.5V Power Supply
k=+1.2V Power Supply
l=-5.8V Power Supply
m=Fan#1 State
n=Fan#2 State (SEE NOTE 4)
o=Heatsink Temp
p=Overtemp Shutdown
q=llC Status
r=Forward Power Alarm
s=Flash Checksum
t=FPGA Done
u=BUC Lock Detect (SEE NOTE 4)
v=External Ref Lock Detect (SEE NOTE 4)
w=LNB Current (SEE NOTE 4)
x=Redundancy Switch Condition (SEE NOTE 4)