Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–16 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Power FET
Current Status
depending on
the number of
installed FETs
Returns the power values of installed FETs, comma-delimited, in concise format.
NOTE: This is the condensed version of the RFS query.
EXAMPLE: <0001/CFS?{CR}
>0001/CFS=xxx,xxx,x.x,x.x,……….,x.x,{CR}{LF}
x
Identification
Sets or returns the user-defined label for the unit or station.
NOTE: The 48-character string is entered as one line, but it is read back from the
unit as two 24-byte lines of information.
Default Setting: ------CID MESSAGE-------
------------------------
COMMAND EXAMPLE: <0001/CID= Station #001--SSPA #01--{CR}
>0001/CID={CR}{LF}
QUERY EXAMPLE: <0001/CID?{CR}
>0001/CID={CR}
Station #001{CR}
CID?
CID*
Current
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in
the form xxx.x.
Default value: 000.0
NOTES:
1) This command returns a mode error if the LNB current source output has
not been enabled first (see LCS command).
2) The LNB current alarm point is then determined by the calibrated LNB
reference point, and the LNB current window setting (see LCW command).
3) The CLC query returns the value that was stored during the LNB current
calibration.
COMMAND EXAMPLE: <1/CLC=xxx.x{CR} (where xxx.x is the calibrated LNB
current value in mA)
QUERY EXAMPLE: <1/CLC?{CR}
CLC?
CLC*