Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–18 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Log
Clears the statistics log entries in the form x, where x=1.
CSL?
Data
Clears the trending data in the form x, where:
x=1
CTD?
CTD*
Status*
Returns the Maintenance status of the unit, in the form aaaa;bbbbb;ccc, response
is semicolon-delimited, where:
aaaa=Remote Unit Address
bbbbb=Remote Baud Rate
ccc=Reference oscillator tuning voltage DAC value (present only if a reference
oscillator is installed)
EXAMPLE: <0001/CUS?{CR}
>0001/CUS=aaaa;bbbbb;ccc{CR}{LF}
Window Enable
Sets or returns the LNB current window alarm in the form x, where:
0=Disabled (DEFAULT)
1=Enabled (SEE NOTE)
NOTE: If disabled, the LCW value will be retained, but unused.
COMMAND EXAMPLE: <0001/CWE=0{CR}
CWE?
CWE *
(by Month)*
Sets or returns the Real-Time-Clock date in the form mmddyy, where:
mm=month of the year (01 to 12)
dd=day of the month (01 to 31)
yy=year (00 to 96) (2000 to 2096)
COMMAND EXAMPLE (date=April 25, 2016): <0001/DAT=042516{CR}
DAT?
DAT*