LPOD C- / Ku-Band Outdoor Amplifier/ Block Up Converter (BUC) Revision 3
Appendix B MN-LPOD
B–30
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are printable ASCII
characters)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Summary Fault
Status
E
N/A 1 byte
Query only.
Indicates the condition of the summary fault relay.
Where:
0 = Not Faulted (SumFLT_COM J6 pin K is not
connected to SumFLT_NC J6 pin M)
1 = Faulted (SumFLT_COM J6 pin K is connected to
SumFLT_NC J6 pin M)
Example: <1/SFS?
>0001/SFS=0’cr’’lf’
SFS= SFS?
SFS=x
(See Description
of Arguments for
details)
Serial Number N/A 9 bytes Query only.
Used to Query the unit’s nine-digit serial number in the
form of SNO=xxxxxxxxx, where:
xxxxxxxxx is the unit’s nine-digit serial number.
Note: this command is functionally identical to RSN.
Example: <1/SNO?’cr’
>0001/SNO=072282040’cr’’lf’
SNO= SNO? SNO=xxxxxxxxx
(See Description
of Arguments for
details)
Remote Address SPA= 4 bytes Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: <1/SPA=0412’cr’
>0001/SPA=’cr’’lf’
Default Value: 0001
SPA=
SPA?
SPA*
SPA?
SPA=xxxx
(Same format as
command
arguments)
Set Statistics
Interval
SSI= 2 bytes Command or Query.
Sets the interval at which statistics are logged.
Minimum resolution is 1 minute, maximum is 99
minutes.
Example: <1/SSI=90’cr’
>0001/SSI=’cr’’lf’
Default Value: 90
SSI=
SSI?
SSI? SSI=xx
(Same format as
command
arguments)
Software
Revision
N/A 34-37 bytes Query only.
Unit returns the value of the internal software revision
installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
SWR= SWR? SWR=Boot:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz
(See Description
of Arguments for
details)