LPOD C-/Ku-Band Outdoor Amplifier/Block Up Converter Revision 3
Ethernet Management MN-LPOD
4–3
4.3.3 SNMP Traps
The LPOD has the ability to send out SNMP traps when certain events occur in the unit. The
LPOD sends out traps when a fault occurs in the unit. A trap is sent both when a fault occurs and
is cleared.
The LPOD supports both SNMPv1 traps and SNMPv2 notifications. Which style of traps the
LPOD sends can be configured by the user using the lpodSNMPTrapVersion OID.
The following are the MIB2 v1traps / v2 notifications that the LPOD supports:
MIB2 SNMPv1 trap: Authentication Failure 5
MIB2 SNMPv2 notifications: Authentication Failure 1.3.6.1.6.3.1.1.5.5
The following tables are the Faults v1 traps / v2 notifications that the LPOD supports.
Faults SNMPv1 traps:
lpodPowerSupply24V1StatusV1 62474801
lpodPowerSupply24V2StatusV1 62474802
lpodPowerSupplyLNBStatusV1 62474803
lpodPowerSupply13VStatusV1 62474804
lpodPowerSupply10VStatusV1 62474805
lpodRFPowerSupply10V1StatusV1 62474806
lpodRFPowerSupply10V2StatusV1 62474807
lpodPowerSupply7V8TStatusV1 62474808
lpodPowerSupply5V8TStatusV1 62474809
lpodPowerSupply2V5TStatusV1 62474810
lpodPowerSupply1V2TStatusV1 62474811
lpodPowerSupplyNeg5V8TStatusV1 62474812
lpodFan1StatusV1 62474813
lpodFan2StatusV1 62474814
lpodTemperatureStatusV1 62474815
lpodShutdownStatusV1 62474816
lpodI2CStatusV1 62474817
lpodForwardPowerStatusV1 62474818
lpodChecksumStatusV1 62474819
lpodFPGADoneStatusV1 62474820