2 For your safety
Intended use
SteamhumidiersCondairMk5areintendedexclusivelyfordirect or indirect room hu-
midication or for humidication in laboratory and process applications withinthe
speciedoperatingconditions.Anyothertypeofapplication,withoutthewrittenconsent
ofyoursupplier,isconsideredasnotconformingwiththeintendedpurpose.Themanu-
facturer/suppliercannotbemadeliableforanydamagesresultingfromimproperuse.The
user bears full responsibility.
Operation of the equipment in the intended manner requires that all the information in
these instructions is observed (in particular the safety instructions).
General safety instructions
– ThesteamhumidierCondairMk5mustonlybeinstalled,operatedservicedandin
all cases repaired only by persons who are adequately qualiedtoundertakesuch
workandarewellacquaintedwiththeproduct.Ascertainingthequalicationsisthe
customer‘s responsibility.
Caution, danger of electric shock! The Condair Mk5 is operated with mains voltage.
Before commencing workontheCondairMk5,theunitistoberendered inopera-
tiveinaccordancewithsection6.3andpreventedfromfurtherinadvertentoperation(
isolateunitfromtheelectricalpowersupply,isolatewatersupply).
Observe all local safety regulations.
relating to the operation of mains-operated electrical and electronic equipment
and the provision of water, steam and electrical installations
– Poorlymaintainedhumidicationsystemscanendangerhealth.The servicing inter-
vals should therefore be adhered to without reservation and the servicing work
carried out correctly.
If it is suspected that safe operation is no longer possible,thentheCondairMk5
should immediately be shut down and secured against accidental power-up. This
canbethecaseunderthefollowingcircumstances:
– iftheCondairMk5isdamaged
– iftheCondairMk5isnolongeroperatingcorrectly
– ifconnectionsand/orpipingarenotsealedorcablesareloose
– TheCondairMk5mustonly be operated under the specied operating conditions
(seesection7).
– TheCondairMk5isprotectedaccordingtoIP21.Makesuretheunitsareinstalledin
a drip-proof location
Caution! IftheCondairMk5isinstalledinanareawithoutawaterdrain,watersensors
mustbettedinthearea,suchthatintheeventofleakageinthewatersystem,the
waterfeedissafelyshutoff.
Caution, danger of corrosion! In order to avoid damage, no corrosion-sensitive
components should be located in the area of the aerosol streams.
No work/repairshouldbecarriedoutontheCondairMk5otherthanthatdescribedin
these instructions.
– Useexclusivelyoriginal accessories and spare parts available from your supplier.
No modications must be undertakenontheCondairMk5withouttheexpresswrit-
ten consent of the manufacturer.