Parameter
structure
Keypad and
display
Parameter x.00
Parameter description
format
Advanced parameter
descriptions
Serial comms
protocol
Performance
Menu 6
Mentor MP Advanced User Guide 101
Issue Number: 4 www.controltechniques.com
Setting this parameter to 0 will disable the drive. It must be at 1 for the drive to run.
When this parameter is set up correctly for the local currency, Pr 6.26 will give an instantaneous read out of running cost.
If this parameter is one the energy meter (Pr 6.24 and Pr 6.25) is reset and held at zero.
To enable the feature that indicates to the user when a filter change is due Pr 6.18 should be set to the time between filter changes.
When the drive is running, Pr 6.27 is reduced each time the runtime timer hour increments (Pr 6.23) until Pr 6.27 reaches 0, at which point Pr 6.19 is
set to 1 to inform the user that a filter change is required. When the user has changed the filter, resetting Pr 6.19 to 0 will indicate to the drive that the
change has been done and Pr 6.27 will be reloaded with the value of Pr 6.18. Pr 6.27 can be updated with the value of Pr 6.18 at any time by setting
and clearing this parameter manually.
The powered-up clock always starts at zero each time the drive is powered-up. The user can change the time from the keypad, serial comms or an
application module. If the data is not written with the various parts in the correct range (i.e. minutes are greater than 59, etc.) the clock is set to zero
on the next minute. This clock may be used for time stamping the trip log if Pr 6.28 = 0. This parameter is used in conjunction with Pr 6.21.
6.15 Drive enable
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
1 111
Default 1
Update rate 4 ms read
6.16 Electricity cost per kWh
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
1111
Range 0.0 to 600.0 currency units per kWh
Default 0.0
Update rate Background read
6.17 Reset energy meter
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Default 0
Update rate Background read
6.18 Time between filter changes
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Range
0 to 30,000 hrs
Default
0
Update rate
Background read
6.19 Filter change required / change done
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111
Default 0
Update rate Background read/write
6.20 Powered-up time: years.days
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
311111
Range 0 to 9.364 Years.Days
Update rate Background write

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques Mentor MP and is the answer not in the manual?

Control Techniques Mentor MP Specifications

General IconGeneral
BrandControl Techniques
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals