5. Press the key to save (or the button to keep the old parameters)
and to access to the TEST EXECUTION screen;
Fig. 4-24
6. When ready, turn ON the pump motor by pressing the relevant switch (note that the
pump motor switch is self retaining when the mains electricity supply is connected);
in the meantime, set lever A up and lever B back on the flow control valve (rapid
approach phase);
Fig. 4-25
7. Before the sample comes in touch with the machine upper platen, zero the load
reading on the WIZARD 2 display by pressing the key. This may be
necessary to eliminate loads which may be indicated because of friction of the thrust
group or the effect of the weight of distance pieces;
NOTE:
Do not zero the load reading once the sample has been subjected to loading.