120
Curtis 1298 Manual, OS 11
8 — DIAGNOSTICS & TROUBLESHOOTING
72 PDO Timeout 1. Time between CAN PDO messages Set: Time between CAN PDO messages
ShutdownInterlock;
received exceeded the PDO received exceeded the PDO Timeout
CAN NMT State set Timeout Period. Period.
to Pre-operational.
Clear: Cycle KSI or receive CAN NMT
message.
73 Stall Detected 1. Stalled motor. Set: No motor encoder movement detected.
ShutdownEMBrake;
2. Motor encoder failure.
Clear: Either cycle KSI, or
ShutdownThrottle;
3. Bad crimps or faulty wiring. detect valid motor encoder signals while
Control Mode changed to 4. Problems with power supply for operating in LOS mode and return
LOS (Limited Operating
the motor encoder. Throttle Command = 0 and
Strategy).
5. See Monitor menu » Motor: Motor RPM = 0.
Motor RPM.
74 Fault On Other Traction Dual Drive fault: see Dual Drive manual.
Controller
75 Dual Severe Fault Dual Drive fault: see Dual Drive manual.
87 Motor Characterization Fault 1. Motor characterization failed during Set: Motor characterization failed during
ShutdownMotor;
characterization process. See Monitor the motor characterization process.
ShutdownMainContactor; menu » Controller: Motor
Clear: Correct fault; cycle KSI.
ShutdownEMBrake;
Characterization Error for cause:
ShutdownThrottle;
0=none
FullBrake;
1=encoder signal seen, but step size
ShutdownPump.
not determined; set Encoder Step
Size manually
2=motor temp sensor fault
3=motor temp hot cutback fault
4= controller overtemp cutback fault
5=controller undertemp cutback fault
6=undervoltage cutback fault
7=severe overvoltage fault
8=encoder signal not seen, or one or
both channels missing
9=motor parameters out of character-
ization range.
89 Motor Type Fault 1. The Motor_Type parameter value Set: Motor_Type parameter is set to an
ShutdownMotor;
is out of range. illegal value.
ShutdownMainContactor;
Clear: Set Motor_Type to correct value
ShutdownEMBrake;
and cycle KSI.
ShutdownThrottle;
FullBrake;
ShutdownPump.
91
VCL/OS Mismatch 1. The VCL software in the controller Set: VCL and OS software do not match;
does not match the OS software in when KSI cycles, a check is made to verify
the controller. that they match and a fault issued when
they do not.
Clear: Download the correct VCL and OS
software into the controller.
Table 5 TROUBLESHOOTING CHART, continued
PROGRAMMER LCD DISPLAY
CODE
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake;
ShutdownPump.