xStack® DES-3200 Series Layer 2 Ethernet Managed Switch CLI Reference Manual
18
config serial_port
Used to co
nfigure the serial port.
Purpose
config
serial_port { baud_rate [9600 | 19200 | 38400 | 115200] | auto_logout [never |
2_minutes | 5_minutes | 10_minutes | 15_minutes] } (1)
Syntax
This
command is used to configure the serial port’s baud rate and auto logout
settings.
Description
Parameters
baud_rate [9600 | 19200 | 38400 | 115200] The serial bit rate that will be used to
communicate with the management host. There are four options: 9600, 19200,
38400, and 115200.
never No time limit on the length of time the console can be open with no user
input.
2_minutes The console will log out the current user if there is no user input for 2
minutes.
5_minutes The console will log out the current user if there is no user input for 5
minutes.
10_minutes The console will log out the current user if there is no user input for 10
minutes.
15_minutes The console will log out the current user if there is no user input for 15
minutes.
Only Administrator-level users
can issue this command.
Restriction
s
Example usage:
To configure the baud rate:
DES-3200-28:4#config serial_port baud_rate 115200
Command: config serial_port baud_rate 115200
Success.
DES-3200-28:4#