Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 0
Page 3.7.8
Emergency gear extension 2/3
Continuing
If :
- GEAR UNSAFE red warning light is OFF and
-
GEAR UNSAFE
is OFF and
- 3 green lights are ON :
8 - Exit and / or remain outside icing conditions.
Continue flight at airspeed < 178 KIAS.
Land as soon as practical
End
of procedure
If :
- GEAR UNSAFE red warning light is ON and
-
GEAR UNSAFE
is ON and
- 0 to 3 green lights are ON :
9 - LDG GEAR breaker Push. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 - CHECK DOWN push-button Press. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If :
- hardening of the pump is marked and
- 3 green lights are ON or
- 3 green lights are ON and flickering while pressing the CHECK DOWN
push-button :
11 - Land
End of procedure