Emergency gear extension 3/3
► Continuing
If :
- emergency pump remains soft or
- one (or more) green light(s) is(are) not ON and / or flickering while pressing
the CHECK DOWN push-button :
A gear unlock condition is confirmed.
Recycle the landing gear as follows :
12 - By-pass selector Unlock / Push. . . . . . . . . . . . . . . . . . . . . . . . . . .
13 - Wait one minute.
14 - LANDING GEAR lever UP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
At airspeed < 150 KIAS
15 - Perform landing gear extension attempts in the normal mode
whil
e applying positive load factors during the maneuver as well
as skidding.
In case of failure :
16 - Perform procedure Landing with unlocked. . . . . . . . . . . .
main landing gear
or Landing with defective nose landing gear
Refer to following procedures
▲ CAUTION ▲
If one main landing gear is not down, it is recommended to land with
landing gear up - refer to procedure Landing with gear up in the
following procedures.
▲
End of procedure.