Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 0
Page 3.9.1
3.9 - Electrical system
BAT AMP
Indicates that battery current is over 50 A while on ground.
After starting the engine with airplane power, a battery charge over 50 amperes is
normal.
CAUTION
Do not take off if battery charge is over 50 A.
If this indication remains steady at a high value :
It may be due to a battery or generation system failure.
End of procedure.
BAT OFF
Indicates that :
- the SOURCE selector has been positioned on OFF or
- the battery plug is disconnected
Fly the airplane
1 - SOURCE selector OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - SOURCE selector BATT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If warning persists :
Land as soon as possible
3 - Airplane mains voltage Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End of procedure.