12.7.2 Power Ratings for Mains Voltage 208–240 V
Table 45: Power Ratings in Mains 208–240 V, 50 Hz, 3~
Enclo-
sure
size
Drive
type
Input
current
I
in
(1)
Low load-
ability: I
L
[A]
(2)
Low load-
ability:
10% over-
load I [A]
High
loadabili-
ty: I
H
[A]
(2)
High
loadabili-
ty: 50%
overload I
[A]
Loadabili-
ty: Max I
S
2 s
Motor
shaft pow-
er
(3)
: 10%
overload
40°C [kW]
Motor
shaft pow-
er
(3)
: 50%
overload
50°C [kW]
FR4 0003 3.7 3.7 4.1 2.4 3.6 4.8 0.55 0.37
0004 4.8 4.8 5.3 3.7 5.6 7.4 0.75 0.55
0007 6.6 6.6 7.3 4.8 7.2 9.6 1.1 0.75
0008 7.8 7.8 8.6 6.6 9.9 13.2 1.5 1.1
0011 11 11.0 12.1 7.8 11.7 15.6 2.2 1.5
0012 12.5 12.5 13.8 11.0 16.5 22.0 3.0 2.2
FR5 0017 17.5 17.5 19.3 12.5 18.8 25.0 4.0 3.0
0025 25 25 27.5 17.5 26.3 35.0 5.5 4.0
0031 31 31 34.1 25.0 37.5 50.0 7.5 5.5
FR6 0048 48 48 52.8 31.0 46.5 62.0 11.0 7.5
0061 61 61.0 67.1 48.0 72.0 96.0 15.0 11.0
FR7 0075 75 75.0 83.0 61.0 92.0 122.0 22.0 15.0
0088 88 88.0 97.0 75.0 113.0 150.0 22.0 22.0
0114 114 114.0 125.0 88.0 132.0 176.0 30.0 22.0
FR8 0140 140 140.0 154.0 105.0 158.0 210.0 37.0 30.0
0170 170 170.0 187.0 140.0 210.0 280.0 45.0 37.0
0205 205 205.0 226.0 170.0 255.0 340.0 55.0 45.0
FR9 0261 261 261.0 287.0 205.0 308.0 410.0 75.0 55.0
0300 300 300.0 330.0 245.0 368.0 490.0 90.0 75.0