0-20 Display Line 1.1 Small
Option: Function:
[1614] Motor current Phase current of the motor
measured as eective value.
[1615] Frequency [%] Motor frequency, that is the output
frequency from the frequency
converter in percent. The frequency
% value is based upon the
frequency in parameter 4-19 Max
Output Frequency.
[1616] Torque [Nm] Present motor load as a percentage
of the rated motor torque.
[1617] Speed [RPM] Motor speed reference. Actual
speed depends on slip compen-
sation being used (compensation
set in parameter 1-62 Slip Compen-
sation). If not used, actual speed is
the value read in the display minus
motor slip.
[1618] Motor Thermal Thermal load on the motor,
calculated by the ETR function. See
also parameter group 1-9* Motor
Temperature.
[1619] Thermistor
Sensor
Temperature
[1620] Motor Angle
[1622] Torque [%] Shows the actual torque produced,
in percentage.
[1623] Motor Shaft
Power [kW]
[1624] Calibrated
Stator
Resistance
[1626] Power Filtered
[kW]
[1627] Power Filtered
[hp]
[1630] DC Link
Voltage
Intermediate circuit voltage in the
frequency converter.
[1631] System Temp.
[1632] Brake
Energy /s
Present brake power transferred to
an external brake resistor.
Stated as an instantaneous value.
[1633] Brake Energy
Average
Brake power transferred to an
external brake resistor. The mean
power is calculated continuously for
the most recent 120 s.
[1634] Heatsink
Temp.
Present heat sink temperature of
the frequency converter. The cut-
out limit is 95 ±5 °C; cutting back
in occurs at 70 ± 5 °C.
0-20 Display Line 1.1 Small
Option: Function:
[1635] Inverter
Thermal
Percentage load of the inverters.
[1636] Inv. Nom.
Current
Nominal current of the frequency
converter.
[1637] Inv. Max.
Current
Maximum current of the frequency
converter.
[1638] SL Controller
State
State of the event executed by the
control.
[1639] Control Card
Temp.
Temperature of the control card.
[1642] Service Log
Counter
[1643] Timed Actions
Status
See parameter group 23-0* Timed
Actions.
[1645] Motor Phase U
Current
[1646] Motor Phase V
Current
[1647] Motor Phase
W Current
[1650] External
Reference
Sum of the external reference as a
percentage, that is the sum of
analog/pulse/bus.
[1652] Feedback[Unit] Reference value from programmed
digital input(s).
[1653] Digi Pot
Reference
View the contribution of the digital
potentiometer to the actual
reference feedback.
[1654] Feedback 1
[Unit]
View the value of feedback 1. See
also parameter group 20-0* FC
Closed Loop.
[1655] Feedback 2
[Unit]
View the value of feedback 2. See
also parameter group 20-0* FC
Closed Loop.
[1656] Feedback 3
[Unit]
View the value of feedback 3. See
also parameter group 20-0* FC
Closed Loop.
[1658] PID Output
[%]
Returns the drive closed-loop PID
controller output value in percent.
[1659] Adjusted
Setpoint
[1660] Digital Input Shows the status of the digital
inputs. Signal low=0; Signal high=1.
Regarding the order, see
parameter 16-60 Digital Input. Bit 0
is at the far right.
[1661] Terminal 53
Switch Setting
Setting of input terminal 53.
Current=0; Voltage=1.