DC Supply Range: 9.0 to 36.0 V-DC.
DC power consumption:
300 mA-DC max. @12V-DC
150 mA-DC max. @24V-DC
Alternator voltage: 0 to 330 V-AC (Ph-N), 0 to 570V Ph-Ph
Alternator frequency: 0-100 Hz.
Mains voltage: 0 to 330 V-AC (Ph-N) , 0 to 570V Ph-Ph
Mains frequency: 0-100 Hz.
Current Inputs: from current transformers. ../5A.
CT Range: 5/5A to 5000/5A
VT Range: 0.1/1 to 6500 / 1
kW Range: 0.1kW to 65000 kW
Accuracy:
Voltage: 0.5%+1digit
Current: 0.5%+1 digit
Frequency: 0.5%+1 digit
Power(kW,kVAr): 1.0%+2digit
Power factor: 0.5 %+1digit
Digital inputs: input voltage 0 to 36 V-DC.
Analog input range: 0-5000 ohms.
DC Outputs: Protected mosfet semiconductor outputs, rated 1Amp@28V-DC
Cranking dropouts: survives 0V for 100ms.
Charge Alternator Excitation: 100mA @12VDC, 200mA @24VDC
USB Device: USB 2.0 Full speed
Operating temperature: -20°C to 70°C (-4 to +158 °F).
Storage temperature: -40°C to 80°C (-40 to +176°F).
Maximum humidity: 95% non-condensing.
IP Protection: IP54 from front panel, IP30 from the rear.
Dimensions: 133 x 107 x 47mm (WxHxD)
Panel Cut-out Dimensions: 117 x 87 mm minimum.
Weight: 250 g (approx.)
Case Material: High Temperature, non-flammable, ROHS compliant ABS/PC
Mounting: Flush mounted with rear retaining plastic brackets.
EU Directives Conformity
-2014/35/EC (low voltage)
-2014/30/EC (electro-magnetic compatibility)
Norms of reference:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)
8. TECHNICAL SPECIFICATIONS