D-100 MK2 User Manual Firmware V-6.3
K96D01-EN - 49 -
The unit features more than 400 event logs with date-time stamp and full snapshot of measured values at
the moment that the event has occurred.
Stored values in an event record are listed below:
-event number
-event type / fault definition (see below for various event sources)
-engine hours
-operation mode
-operation status (on-load, on-mains, cranking, etc...)
-engine hours run
-genset phase voltages: L1-L2-L3
-genset phase currents: L1-L2-L3
-genset frequency
-genset total active power (kW)
-genset total power factor
-oil pressure
-engine temperature
-fuel level
-oil temperature
-canopy temperature
-ambient temperature
-engine rpm
-battery voltage
-charge voltage
Possible event sources are various. Every source can be individually enabled or disabled:
Program mode entrance event: recorded with the password level when program mode is entered.
Mode change event: recorded when the operation mode is changed.
Shutdown/loaddump/warning events: recorded when the related fault condition occurs.
11. DISPLAYING EVENT LOGS
10. -
Event enable
selection tab

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datakom D-100 MK2 and is the answer not in the manual?

Datakom D-100 MK2 Specifications

General IconGeneral
BrandDatakom
ModelD-100 MK2
CategoryController
LanguageEnglish

Related product manuals