EasyManua.ls Logo

Datalogic DS8100A

Datalogic DS8100A
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
READING FEATURES
95
9
9.3 PERFORMANCE
The scan rate is 1000 scans/sec.
Refer to the diagrams in par. 9.4 for further details on the reading features. These diagrams
are taken on various resolution sample codes at a 25 C ambient temperature depending on
the conditions listed under each diagram.
9.3.1 Reading Conditions
ANSI Grade B minimum
1000 scans/sec
The following tables describe the requirements for standard applications.
Minimum Code Height for ACR Reading (mm)
45°
30°
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
2/5 Interleaved
Code Resolution
(mm)
0.25
10
11
13
14
16
17
7
8
9
10
12
13
0.30
12
13
14
16
17
19
8
9
10
11
12
14
0.33
12
14
15
17
18
20
8
9
10
12
13
14
0.38
14
15
16
18
19
21
9
10
11
12
14
15
0.50
18
18
20
21
23
24
11
12
13
14
15
17
0.72
24
25
26
27
28
30
15
16
16
18
19
20
1.00
33
33
34
35
36
37
20
20
21
22
23
24
Ratio 3:1
Table 1
Minimum Code Height for ACR Reading (mm)
45°
30°
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code 39
Code Resolution
(mm)
0.25
9
9
11
12
14
15
6
7
8
9
10
11
0.30
10
11
12
13
15
16
7
7
8
10
11
12
0.33
11
11
12
14
15
17
7
8
9
10
11
12
0.38
12
13
13
15
16
18
8
8
9
10
12
13
0.50
15
16
16
17
18
20
9
10
11
12
13
14
0.72
20
21
22
22
23
24
13
13
14
14
15
16
1.00
27
28
29
29
30
31
17
17
18
18
19
20
Ratio 3:1; Interdigit = Module Size
Table 2

Table of Contents

Related product manuals