8.2.2 Genius™ Network Setup Through Master
The Network Setup allows configuring your Local Lonworks Network through the Master
using Genius™.
Three different procedures are available to define the number of network slave scanners,
their label and address according to two main conditions:
automatically assigns random addresses to
slave or Stand Alone scanners.
customizes the network (slave label and
address definition and physical identification
of a specific slave within network), updates
configuration to a file and makes it ready to
be sent to the Master.
automatically performs all the operations of
the Network Wizard apart from the physical
identification of a specific slave scanner.
The Network Setup procedure as described requires Genius™ software
version 1.06 or later. In addition, the Net-Autoset procedure requires
scanner software version 6.40 or later.
1. The first operation to perform is the configuration of your scanner as "Master" from the
Local Device Network Settings item in the Device Menu, see figure below:
Figure 87 – Local Device Network Settings