EasyManua.ls Logo

Datalogic PowerScan Series

Datalogic PowerScan Series
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GS1 DATABAR™ EXPANDED ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
149
GS1 DATABAR™ EXPANDED
The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) sym-
bology.
GS1 DataBar Expanded Enable/Disable
When disabled, the reader will not read GS1 DataBar Expanded bar codes.
GS1 DataBar Expanded to GS1-128 Emulation
When enabled, GS1 DataBar Expanded bar codes will be translated to the GS1-128 label
data format.
$CXBEN00
GS1 DataBar Expanded = Disable
GS1 DataBar Expanded = Enable
$CXBEN01
$CXBU800
GS1 DataBar Expanded to GS1-128 Emulation
= Disable
GS1 DataBar Expanded to GS1-128 Emulation
= Enable
$CXBU801

Table of Contents

Related product manuals