ENTER/EXIT PROGRAMMING MODE WIRELESS FEATURES
298
POWERSCAN™ PD/PM/PBT9600
Bluetooth Radio Output Power
Set this parameter according to the desired radio range of the Reader:
Class 1: max 100 meters
Class 2: max 20 meters
Class 3: max 5 meters
Reducing the maximum radio range can help extend the battery life of the Reader. It can
also reduce the interferences caused to nearby wireless devices that operate in the
same 2.4 GHz frequency band.
NOTE: Changing the BT Security Level setting will unlink the Reader from
the remote device.
$CBTSL01
BT Security Level = Level 1 - lowest
BT Security Level = Level 2
$CBTSL02
$CBTSL03
BT Security Level = Level 3 - highest
$CBTPP00
Bluetooth Output Power = Class 1 (highest)
Bluetooth Output Power = Class 2
$CBTPP01
$CBTPP02
Bluetooth Output Power = Class 3 (lowest)