ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
176
POWERSCAN™ PD/PM/PBT9600
Standard 2 of 5 Check Character Transmission
This feature enables/disables transmission of an optional Standard 2 of 5 check charac-
ter.
Standard 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Standard 2 of 5 symbology.
Variable Length: For variable-length decoding, a minimum length may be set.
Fixed Length: For fixed-length decoding, two different lengths may be set.
$CS2CT00
Standard 2 of 5 Check Character Transmission
= Don’t Send
Standard 2 of 5 Check Character Transmission
= Send
$CS2CT01
$CS2LC00
Standard 2 of 5 Length Control = Variable Length
Standard 2 of 5 Length Control = Fixed Length
$CS2LC01