CODE 128 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
165
Code 128 Set Length 1
This feature specifies one of the bar code lengths for "Code 128 Length Control" on page
164
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 80 characters. See "
Set Length 1" on page 341 for more
detailed programming instructions.
Code 128 Set Length 2
This feature specifies one of the bar code lengths for "Code 128 Length Control" on page
164
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. Length includes the bar code’s data characters
only.
The length can be set from 1 to 80 characters. A setting of 00 specifies to ignore this
length (only one fixed length). See "
Set Length 2" on page 342 for more detailed pro-
gramming instructions.
Select Code 128 Set Length 1 Setting
$CC8L1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix G, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Code 128 Set Length 2 Setting
$CC8L2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix G, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 80 (80 characters)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan Series and is the answer not in the manual?

Datalogic PowerScan Series Specifications

General IconGeneral
ResolutionVaries by model
DimensionsVaries by model
WeightVaries by model
Light SourceVisible Laser Diode
ConnectivityUSB, RS-232, Keyboard Wedge
DurabilityIndustrial Grade
Decode Capability1D and 2D barcodes
InterfaceRS-232, USB, Keyboard Wedge
Humidity5% to 95% non-condensing
IP RatingIP65
Operating Temperature0°C to 50°C

Related product manuals