RF FEATURES
PRODUCT REFERENCE GUIDE
339
RF FEATURES
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their configurations
synchronized. If a reader's configuration is altered by reading programming labels, this
change is automatically transferred and updated in a linked base station. Likewise, if the
base station's configuration is changed using Aladdin or by host commands, then the
reader's configuration will automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and
radio address when address stamping is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent on the ASCII
Chart on
page 394. A setting of 00 specifies no delimiter character.
2. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER.
4. Scan the appropriate two digits from the keypad in
Appendix G, that represent the
hexadecimal characters which were determined in the steps above. You will hear a
two-beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 26 Source Radio Address Delimiter Character Setting Examples
NOTE: This feature only applies if "Source Radio Address Transmission" on
page 292
is enabled
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
STEP
ACTION EXAMPLES
1 Desired Setting
No delimiter
character
, (comma) - (dash)
/ (slash)
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
Appendix G
‘0’ and ‘0’ ‘2’ and ‘C’ ‘2’ and ‘D’ ‘2’ AND ‘F’
5 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan Series and is the answer not in the manual?

Datalogic PowerScan Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals