ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
182
POWERSCAN™ PD/PM/PBT9600
Datalogic 2 of 5 Check Character Transmission
Enable this option to transmit the check character along with Datalogic 2 of 5 bar code
data.
Datalogic 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Datalogic 2 of 5 symbology.
Variable Length: For variable-length decoding, a minimum length may be set.
Fixed Length: For fixed-length decoding, two different lengths may be set.
$CD2CT00
Datalogic 2 of 5 Check Character Transmission
= Don’t Send
Datalogic 2 of 5 Check Character Transmission
= Send
$CD2CT01
$CD2LC00
Datalogic 2 of 5 Length Control = Variable Length
Datalogic 2 of 5 Length Control = Fixed Length
$CD2LC01