AZTEC CODE ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
221
Aztec Code Set Length 1
Specifies one of the bar code lengths for "Aztec Code Length Control" on page 220.
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length
if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in incre-
ments of 0001 (pad with zeroes).
See "
Set Length 1" on page 341 for detailed instructions on setting this feature.
Aztec Code Set Length 2
Specifies one of the bar code lengths for "Aztec Code Length Control" on page 220.
Length 2 is the minimum label length if in Variable Length Mode, or the first fixed length
if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in incre-
ments of 0001 (pad with zeroes).
See "
Set Length 2" on page 342 for detailed instructions on setting this feature.
Select Aztec Code Length 1 Setting
$CAZL1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix G, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
0001 = Length 1 is 1 Character
Select Aztec Code Length 2 Setting
$CAZL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix G, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 is 3,832 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan Series and is the answer not in the manual?

Datalogic PowerScan Series Specifications

General IconGeneral
ResolutionVaries by model
DimensionsVaries by model
WeightVaries by model
Light SourceVisible Laser Diode
ConnectivityUSB, RS-232, Keyboard Wedge
DurabilityIndustrial Grade
Decode Capability1D and 2D barcodes
InterfaceRS-232, USB, Keyboard Wedge
Humidity5% to 95% non-condensing
IP RatingIP65
Operating Temperature0°C to 50°C