Enter/Exit Programming Mode Code 128
122 QuickScan™ I QD24XX/QBT24XX/QM24XX
Code 128 Quiet Zones
This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank
areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or
space in the label.
$CC8LO02(CR)
Code 128 Quiet Zones = Quiet Zones on two sides
$CC8LO03(CR)
Code 128 Quiet Zones = Small Quiet Zones on two sides
DEFAULT
Code 128 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 128
symbology. See page 243 for more informatio
n.
DEFAULT
$CC8LC00(CR)
Code 128 Length Control = Variable Length
$CC8LC01(CR)
Code 128 Length Control = Fixed Length

Table of Contents

Other manuals for Datalogic QuickScan QBT2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QBT2400 and is the answer not in the manual?

Datalogic QuickScan QBT2400 Specifications

General IconGeneral
ConnectivityBluetooth
Battery TypeLithium-Ion
Battery Capacity1400 mAh
IP RatingIP42
Print Contrast Ratio (Minimum)25%
Interfaces SupportedUSB, RS-232, Keyboard Wedge
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft
Radio Range (Open Air)100 m
TypeHandheld
Scan Rate60 frames per second
Resolution0.1 mm
Humidity5 to 95% non-condensing
Light SourceRed LED
Supported Barcodes1D / 2D and postal codes

Related product manuals