EasyManuals Logo

Datalogic QuickScan QBT2400 User Manual

Datalogic QuickScan QBT2400
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #233 background imageLoading...
Page #233 background image
Bluetooth-Only Features Enter/Exit Programming Mode
Product Reference Guide
223
BT SECURITY FEATURES
On the BT system, it is possible to set a (configurable) PIN code to authenticate/connect BT
devices, and encrypt the data.
The BT PIN code can be enabled and configured by reading the bar codes
in the following sec-
tions.
If you are using a BT scanner directly connected to a host through a BT dongle, verify that
the scanner and the BT driver used by the dongle share the same PIN code and the same
security level. Otherwise the connection cannot be established.
Follow these steps to set the PIN code for a scanner:
1. Enable BT Security Mode by scanning the “Enable” ba
r code below.
2. Select a PIN code length of either 4 or 16 characters by scanning the appropriate bar code
in
"Select PIN Code Length" on pa
ge 224.
3. Scan the relevant bar code from "Set PIN Code" on page 22
4, then scan the desired alpha-
numeric characters from the keypad in Appendix D Keypad to set the PIN code.
See page 264 in “References” for more detailed information and examples for this feature.
BT Security Mode
This feature enables/disables authentication and encryption of the BT link. Use the feature "BT
PIN Code" on page 22
4 to specify the length and digits in the PIN code used to authenticate the
BT Link.
DEFAULT
$CBTSE00(CR)
BT Security Mode = Disable
$CBTSE01(CR)
BT Security Mode = Enable
Changing the security mode setting will unlink the devices. If the Automatic Configuration
Update is set to the default “Enabled” setting, the devices must only be relinked. If the
Automatic Configuration Update is set to “Disabled,” the Security Mode setting must also
be updated in the Base Station using Aladdin. After the Base Station has been updated, the
devices must be relinked.

Table of Contents

Other manuals for Datalogic QuickScan QBT2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QBT2400 and is the answer not in the manual?

Datalogic QuickScan QBT2400 Specifications

General IconGeneral
ConnectivityBluetooth
Battery TypeLithium-Ion
Battery Capacity1400 mAh
IP RatingIP42
Print Contrast Ratio (Minimum)25%
Interfaces SupportedUSB, RS-232, Keyboard Wedge
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft
Radio Range (Open Air)100 m
TypeHandheld
Scan Rate60 frames per second
Resolution0.1 mm
Humidity5 to 95% non-condensing
Light SourceRed LED
Supported Barcodes1D / 2D and postal codes