1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
147
Codabar Quiet Zones
Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends
of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
$CCBLO02(CR)
Codabar Quiet Zones = Quiet Zones on two sides
$CCBLO03(CR)
Codabar Quiet Zones = Small Quiet Zones on two sides
DEFAULT
Codabar Length Control
This feature specifies either variable length decoding or fixed length decoding for the Codabar
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CCBLC00(CR)
Codabar Length Control = Variable Length
$CCBLC01(CR)
Codabar Length Control = Fixed Length

Table of Contents

Other manuals for Datalogic QuickScan QBT2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QBT2400 and is the answer not in the manual?

Datalogic QuickScan QBT2400 Specifications

General IconGeneral
ConnectivityBluetooth
Battery TypeLithium-Ion
Battery Capacity1400 mAh
IP RatingIP42
Print Contrast Ratio (Minimum)25%
Interfaces SupportedUSB, RS-232, Keyboard Wedge
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft
Radio Range (Open Air)100 m
TypeHandheld
Scan Rate60 frames per second
Resolution0.1 mm
Humidity5 to 95% non-condensing
Light SourceRed LED
Supported Barcodes1D / 2D and postal codes