1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
163
GS1 DATABAR™ LIMITED
The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology.
GS1 DataBar™ Limited Enable/Disable
When disabled, the reader will not read GS1 DataBar™ Limited bar codes.
DEFAULT
$CLBEN00(CR)
GS1 DataBar™ Limited = Disable
$CLBEN01(CR)
GS1 DataBar™ Limited = Enable
GS1 DataBar™ Limited GS1-128 Emulation
When enabled, GS1 DataBar™ Limited bar codes will be translated to the GS1-128 label data
format.
DEFAULT
$CLBU800(CR)
GS1 DataBar™ Limited GS1-128 Emulation = Disable
$CLBU801(CR)
GS1 DataBar™ Limited GS1-128 Emulation = Enable

Table of Contents

Other manuals for Datalogic QuickScan QBT2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QBT2400 and is the answer not in the manual?

Datalogic QuickScan QBT2400 Specifications

General IconGeneral
ConnectivityBluetooth
Battery TypeLithium-Ion
Battery Capacity1400 mAh
IP RatingIP42
Print Contrast Ratio (Minimum)25%
Interfaces SupportedUSB, RS-232, Keyboard Wedge
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft
Radio Range (Open Air)100 m
TypeHandheld
Scan Rate60 frames per second
Resolution0.1 mm
Humidity5 to 95% non-condensing
Light SourceRed LED
Supported Barcodes1D / 2D and postal codes