TC1200 REFERENCE MANUAL
16
3
Example 1:
1. $S<CR>
Enter Service Mode
2. $CLFCA02<CR>
Write command "Convert to Lower Case" to current configuration
3. $Ar<CR>
Apply and Save Configuration to FLASH (permanent memory) and Exit Service
Mode.
Each configuration parameter setting removes the condition previously active for that
parameter.
Example 2:
1. $S<CR>
Enter Service Mode
2. $HA05<CR>
Select RS232 Interface
3. $Ar<CR>
Apply and Save Configuration to FLASH (permanent memory) and Exit Service
Mode.
Example 3:
1. $+$!<CR>
Read Application Software Release

Table of Contents