EasyManua.ls Logo

Datalogic TC1200 - Digital Outputs Configuration; Power Save Configuration

Datalogic TC1200
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOFTWARE CONFIGURATION STRINGS
21
3
DIGITAL OUTPUTS
Description Parameter Value
OUTPUT 1
Activation Event Disable OUA1 00
Good Read 01
No Read 02
Wrong Code 03
Deactivation Event Disable OUD1 00
Timeout 01
Reading Phase Active 02
Deactivation Timeout 100 to 25500 ms OUT1 n
Active Level Closed OUL1 00
Open 01
OUTPUT 2
Activation Event Disable OUA2 00
Good Read 01
No Read 02
Wrong Code 03
Deactivation Event Disable OUD2 00
Timeout 01
Reading Phase Active 02
Deactivation Timeout 100 to 25500 ms OUT2 n
Active Level Closed OUL2 00
Open 01
n = Hex value from 01 to FF representing the decimal number (x100 ms)
POWER SAVE
Description Parameter Value
Sleep Mode Timeout Disable SLTO 00
10 seconds 01
30 seconds 02
1 minute 03
5 minutes 04
10 minutes 05

Table of Contents