TC1200 REFERENCE MANUAL
26
3
CODE SELECTION
Description Parameter Value
Interleaved 2 of 5 (I 2 of 5)
I 2 of 5 Disable I2EN 00
Enable 01
Code Length Control Variable I2LC 00
Fixed 01
Set Length Length 1 (or Min Length) from 2 to 50 characters (only even numbers) I2L1 v
Length 2 (or Max Length) from 0 or from 2 to 50 characters (only even
numbers)
I2L2 v
Check Options
Check Calculation Disable I2CC 00
Enable Standard(Mod 10) 01
Enable German Parcel 02
Enable DHL 04
Enable Daimler Chrysler 08
Enable Bosch 10
Enable Italian Post 20
Check Tx Disable I2CT 00
Enable 01
Decoding Options
Minimum Reads One Read I2MR 01
Two Reads 02
Three Reads 03
Four Reads 04
Decoding Level Disable I2DL 00
Level 1 01
Level 2 02
Level 3 03
Level 4 04
Level 5 05
Character Correlation Disable I2CO 00
Enable 01
Stitching Disable I2ST 00
Enable 01
Zero Pattern Disable I2ZP 00
Enable 01
v = Hex value from 00 or 02 to 32 representing the decimal number
Standard 2 of 5
Standard 2 of 5 Disable S2EN 00
Enable 01
Code Length Control Variable S2LC 00
Fixed 01
Set Length Length 1 (or Min Length) from 1 to 50 characters S2L1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters S2L2 v
Check Options
Check Calculation Disable S2CC 00
Enable 01
Check Tx Disable S2CT 00
Enable 01
Decoding Options
Minimum Reads One Read S2MR 01
Two Reads 02
Three Reads 03
Four Reads 04
Decoding Level Disable S2DL 00
Level 1 01
Level 2 02
Level 3 03
Level 4 04
Level 5 05
Character Correlation Disable S2CO 00
Enable 01
Stitching Disable S2ST 00
Enable 01
v = Hex value from 00 to 32 representing the decimal number