9.3.8. Active display setting
■The role of the active display
The display is equipped with a dimmer sensor.
When multiple displays are connected, there will be multiple dimmer sensors in a single
ADVANCE System, so it is necessary to decide which dimmer sensor should be used as the
representative.
When the dimmer setting is set to [AUTO], the dimmer sensor of the display configured as
the active display among the multiple displays will be used to sense the ambient brightness
and control the display brightness according to the respective functions of the ADVANCE
System.
To set up an active display, a different display No. must be assigned to each display.
Linking multiple displays with the same display No. will not work properly.
⇒9.4.9 Display number setting [DISPLAY NO.]
■How to check and change the active display
CU OPR (Slide switch position:【LOWER】)
1. Set the slide switch to 【LOWER】.
2. Press the 【RIGHT button】 to display [ACTIVE] in the FD multi-display zone. Each time
you press the 【RIGHT button】, the active display switches.
※If only one display is connected, [ACTIVE] will not be displayed.
⇒9.5.1 Multi-display zone