EasyManua.ls Logo

Dell IDRAC6 - Page 317

Dell IDRAC6
472 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Recovering and Troubleshooting the Managed System 317
Warning System Board System Level:
Current sensor for System Board,
warning event
Current crossed a warning
threshold
Critical System Board System Level:
Current sensor for System Board,
failure event
Current crossed a failure
threshold
Critical CPU<number> <voltage sensor
name>: Voltage sensor for
CPU<number>, state asserted
was asserted
Voltage out of range
Critical System Board <voltage sensor
name>: Voltage sensor for
System Board, state asserted was
asserted
Voltage out of range
Critical CPU<number> <voltage sensor
name>: Voltage sensor for
CPU<number>, state asserted
was asserted
Voltage out of range
Critical CPU<number> Status:
Processor sensor for
CPU<number, IERR was
asserted
CPU failure
Critical CPU<number> Status:
Processor sensor for
CPU<number>, thermal tripped
was asserted
CPU overheated
Critical CPU<number> Status:
Processor sensor for
CPU<number, configuration
error was asserted
Incorrect processor type or in
wrong location
Critical CPU<number> Status:
Processor sensor for
CPU<number>, presence was
deasserted
Required CPU is missing or
not present
Table 20-8. Server Status Screen (continued)
Severity Message Cause

Table of Contents

Related product manuals