342 RACADM Subcommand Overview
• racadm getssninfo -A
"root" 143.166.174.19 "Telnet" "NONE"
• racadm getssninfo -A -u *
"root" "143.166.174.19" "Telnet" "NONE"
• "bob" "143.166.174.19" "GUI" "NONE"
getsysinfo
Table A-8 describes the racadm getsysinfo subcommand.
Synopsis
racadm getsysinfo [-d] [-s] [-w] [-A] [-4] [-6]
Description
The getsysinfo subcommand displays information related to iDRAC6, the
managed server, and the watchdog configuration.
Supported Interfaces
• Local RACADM
• Remote RACADM
• telnet/ssh RACADM
Input
Table A-9 describes the getsysinfo subcommand options.
Table A-7. getssninfo Subcommand Output Example
User IP Address Type Consoles
root 192.168.0.10 Telnet Virtual KVM
Table A-8. getsysinfo
Command Definition
getsysinfo Displays information related to iDRAC6.