Loading...
RACADM Subcommand Overview 351
Description
The getsvctag subcommand displays the service tag of the host system.
Supported Interfaces
•Local RACADM
Remote RACADM
telnet/ssh RACADM
racreset
Table A-14 describes the racreset subcommand.
NOTE: When you issue a racreset subcommand, iDRAC6 may require up to two
minutes to return to a usable state.
Synopsis
racadm racreset
Description
The racreset subcommand issues a reset to iDRAC6. The reset event is
written into iDRAC6 log.
Examples
racadm racreset
Start iDRAC6 soft-reset sequence.
Supported Interfaces
•Local RACADM
Remote RACADM
telnet/ssh RACADM
Table A-14. racreset
Subcommand Definition
racreset Resets iDRAC6.