EasyManua.ls Logo

Dell IDRAC6 - Cfgvirmediabootonce (ReadWrite)

Dell IDRAC6
472 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iDRAC6 Enterprise Property Database Group and Object Definitions 435
2 = Auto Attach
Default
0
Description
This object is used to attach virtual devices to the system via the USB bus.
When the devices are attached the server will recognize valid USB mass
storage devices attached to the system. This is equivalent to attaching a local
USB CDROM/floppy drive to a USB port on the system. When the devices
are attached you then can connect to the virtual devices remotely using
iDRAC6 Web interface or the CLI. Setting this object to 0 will cause the
devices to detach from the USB bus.
NOTE: You must restart your system to enable all changes.
cfgVirMediaBootOnce (Read/Write)
Legal Values
1 (Enabled)
0 (Disabled)
Default
0
Description
Enables or disables the virtual media boot-once feature of iDRAC6. If this
property is enabled when the host server is rebooted, this feature will attempt
to boot from the virtual media devices—if the appropriate media is installed
in the device.
cfgVirMediaKeyEnable (Read/Write)
Legal Values
1 (TRUE)
0 (FALSE)

Table of Contents