320 Recovering and Troubleshooting the Managed System
Non-Recoverable CPU Bus PERR: Processor sensor,
transition to non-recoverable
was asserted
The processor bus PERR
entered a non-recoverable state
Non-Recoverable CPU Init Err: Processor sensor,
transition to non-recoverable
was asserted
The processor initialization
entered a non-recoverable state
Non-Recoverable CPU Machine Chk: Processor
sensor, transition to
non-recoverable was asserted
The processor machine check
entered a non-recoverable state
Critical Memory Spared: Memory sensor,
redundancy lost
( <DIMM Location> ) was
asserted
Memory spare is no longer
redundant
Critical Memory Mirrored: Memory
sensor, redundancy lost
( <DIMM Location> ) was
asserted
Mirrored memory is no longer
redundant
Critical Memory RAID: Memory sensor,
redundancy lost
( <DIMM Location> ) was
asserted
RAID Memory is no longer
redundant
Warning Memory Added: Memory sensor,
presence ( <DIMM Location> )
was deasserted
Added memory module was
removed
Warning Memory Removed: Memory
sensor, presence ( <DIMM
Location> ) was deasserted
Memory module was removed
Critical Memory Cfg Err: Memory sensor,
configuration error
( <DIMM Location> ) was
asserted
Memory configuration is
incorrect for the system
Warning Mem Redun Gain: Memory
sensor, redundancy degraded
( <DIMM Location> ) was
asserted
Memory redundancy is
downgraded but not lost
Table 20-8. Server Status Screen (continued)