Recovering and Troubleshooting the Managed System 323
Critical Mem Overtemp: Memory sensor,
correctable ECC <DIMM
Location> was asserted
Memory module overheating
Critical Mem Fatal SB CRC: Memory
sensor, uncorrectable ECC
was asserted
South bridge memory failed
Critical Mem Fatal NB CRC: Memory
sensor, uncorrectable ECC
was asserted
North bridge memory failed
Critical WatchDog Timer: Watchdog
sensor, reboot was asserted
Watch dog timer caused
system to reboot
Critical WatchDog Timer: Watchdog
sensor, timer expired was asserted
Watch dog timer expired but
no action taken
Warning Link Tuning: Version Change
sensor, successful software or
F/W change was deasserted
Failed to update link tuning
setting for proper NIC operation
Warning Link Tuning: Version Change
sensor, successful hardware
change <device slot number>
was deasserted
Failed to update link tuning
setting for proper NIC operation
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to program virtual
MAC address (Bus # Device #
Function #) was asserted
FlexAddress could not be
programmed for this device
Critical LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz <location>)
was asserted
Option ROM does not support
FlexAddress or linking tuning
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to get link tuning or
flex address data from
BMC/iDRAC6 was asserted
Failed to obtain linking tuning
or FlexAddress information
from BMC/iDRAC6
Table 20-8. Server Status Screen (continued)
Severity Message Cause