A sensor in the front panel of a node has exceeded the specified threshold.
Description
This event can occur intermittently without harm to the system.
Administrator action
1. Cancel or quiet the event.
2. If the event recurs, shutdown and restart the node by completing the following steps:
Connect to the affected node through SSH or serial cable.
Shut down the node by running the following command:
shutdown -p now
Wait for the node to shut down, and then disconnect both power supply cables.
Press the power button on the node to discharge any remaining stored power.
Reconnect the power cables and then start the node.
3. (HD400 only.) Re-seat the front panel connector by checking that the ribbon cable is properly attached and properly seated.
4. (All other nodes.) Re-seat the front panel.
5. Move the front panel from a functioning node to the affected node and see if the event clears.
6. Install the front panel from the affected node on another node to determine if the problem is with the front panel or with the
node.
If the problem follows the front panel, contact Technical Support to request a new front panel.
If the above steps do not resolve the issue, gather logs, and then contact Technical Support for additional troubleshooting. For
instructions on how to gather cluster logs, see Gathering cluster logs.
900060002
A power supply fan in the node might have failed.
Description
If the fan speed temporarily falls out of optimal range for less than a minute or so and the event does not repeat, this event
might be a false alarm.
Administrator action
Follow the instructions in Event notification: Fan speed out of spec, article 000083406 to determine if this event is a false
alarm.
If this event is not a false alarm, contact Technical Support.
134
Hardware events

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerScale OneFS and is the answer not in the manual?

Dell PowerScale OneFS Specifications

General IconGeneral
BrandDell
ModelPowerScale OneFS
CategoryStorage
LanguageEnglish

Related product manuals