EasyManuals Logo

Dell PowerScale OneFS User Manual

Dell PowerScale OneFS
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
100010052
A drive is no longer appearing as part of the cluster and is being smartfailed.
Description
A drive appears to be missing from the cluster and the smartfail process has been initiated to officially remove the drive from
the cluster. The event message provides you with the chassis serial number, node, sled, the drive slot number within the sled,
drive type, and Logical Number (LNUM) of the drive.
Administrator action
Wait for the smartfail process to complete, then replace the drive with a new drive according to the instructions in the
PowerScale Drive Replacement Guide for your platform.
100010053
A drive that is write-cache enabled was installed in a Generation 6 platform. Write-cache enabled drives are not compatible with
Generation 6 nodes.
Description
A write-cache enabled drive was installed in a 6th Generation node and is not compatible with the node. The event message
provides you with the chassis serial number, node, sled, the drive slot number within the sled, drive type, and Logical Number
(LNUM) of the drive.
Administrator action
Replace the drive with a compatible drive according to the instructions in the PowerScale Drive Replacement Guide for your
platform.
100010054
A drive was inserted in a bay that is disabled.
Description
A drive was installed in a sled that is in a bay that is disabled. While, OneFS recognizes service requests for devices in disabled
bays, you must resolve the issue with the disabled bay before you can service a drive. To ensure proper functionality, remove
the drive from the chassis immediately. The event message provides you with the chassis serial number, node, sled, the drive
slot number within the sled, drive type, and Logical Number (LNUM) of the drive.
Administrator action
Remove the drive from the sled that is in the disabled bay. After you have resolved the issue with the disabled bay, re-install the
drive according to the instructions in the PowerScale Drive Replacement Guide for your platform.
Software events
49

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerScale OneFS and is the answer not in the manual?

Dell PowerScale OneFS Specifications

General IconGeneral
BrandDell
ModelPowerScale OneFS
CategoryStorage
LanguageEnglish

Related product manuals